Used Siemens 4000A 600V air breaker model RL-4000, manually operated, drawout with static trip III relay with LSIG functions and 4000A CTs

Used Siemens RL-4000 air circuit breaker rated 4000A, 600V, featuring manual operation and a drawout design for easy maintenance. Equipped with a Static Trip III relay offering LSIG protection (long-time, short-time, instantaneous, and ground fault) and includes 4000A current transformers. Ideal for industrial and commercial power distribution applications.

SKU: 34757 Categories: , Tags: , , , , Brand:

Description

Siemens RL-4000 Air Circuit Breaker – 4000A, 600V, Drawout, Static Trip III LSIG – Used

Reliable and fully serviceable Siemens RL-4000 air circuit breaker available for use. This unit is rated at 4000 amps and 600 volts, making it suitable for a wide range of industrial and commercial power distribution systems.

Designed with a drawout configuration, this breaker allows for quick installation, removal, and maintenance—ideal for minimizing downtime in critical applications. The manual operating mechanism ensures dependable performance without reliance on external control power.

Equipped with a Static Trip III electronic trip unit, this breaker provides complete LSIG protection (Long-Time, Short-Time, Instantaneous, and Ground Fault), offering enhanced system protection and coordination. Includes 4000A current transformers for sensing and protection.

Specifications:

  • Manufacturer: Siemens
  • Model: RL-4000
  • Amperage: 4000A
  • Voltage: 600V
  • Interrupting rating (AIC):  100KA at 600V
  • Type: Air Circuit Breaker (ACB)
  • Mounting: Drawout
  • Operation: Manual
  • Trip Unit: Static Trip III
  • Protection: LSIG (Long-Time, Short-Time, Instantaneous, Ground Fault)
  • CTs: 4000A Included
  • Condition: Used

Additional Details:

  • Clean and visually inspected
  • Contacts and arc chutes in good condition
  • Stored in a dry, climate-controlled environment
  • Ideal for replacement or spare inventory

Applications:
Perfect for switchgear systems, industrial facilities, manufacturing plants, and commercial buildings requiring reliable circuit protection.

Additional information

Switchgear Amperage

4000A

Switchgear Trip Amperage

4000A

Switchgear Voltage

600V

Switchgear Make/Manufacturer

Siemens

Switchgear Phase

3

Switchgear Enclosure type

NEMA 1 – Indoor

Switchgear Catalogue number

RL-4000

Switchgear Condition

Used

Switchgear Operation

Manual

Switchgear Rack Type

Draw out

Switchgear Interrupting rating (KA)

100 KA

Switchgear Relay & Functions

Static Trip III & LSIG

Switchgear Control Voltage - Charge

N/A

Switchgear Control Voltage - Trip

N/A

Switchgear Control Voltage - Close

N/A